  5. Wire bond degradation under thermo- and pure mechanical loading
 
  • Details

Wire bond degradation under thermo- and pure mechanical loading

Publisher
Elsevier
Source
Microelectronics Reliability, 76–77(September 2017), 373-377
Date Issued
2017-09
Author(s)
Czerny, Bernhard  
Pedersen, Kristian Bonderup 
Nielsen, Dennis A. 
Khatibi, Golta 
Iannuzzo, Francesco 
Popok, Vladimir N. 
Pedersen, Kjeld 
DOI
10.1016/j.microrel.2017.07.055
Abstract
This paper presents a fundamental study on degradation of heavy Al bond wires typically used in high power modules. Customized samples are designed to only consist of Al bond wires on standard Si diodes. These samples are subjected to pure mechanical and passive thermal cycling to investigate the bond degradation behavior on a simple system as well as compare these two test methods. Although an appreciable difference in fracture behavior is observed between these two methods, both provide correlation between the number of cycles and degree of degradation, especially in the case of the passive thermal test. To enable investigation of degradation rate a large number of bond interfaces is analyzed and they are found to follow conventional accepted fracture laws like Paris-Erdogan. With additional work this could enable the possibility of obtaining empirical parameters to be used in actual physics based lifetime laws.
URI
http://hdl.handle.net/20.500.11790/1647
Type
Wissenschaftlicher Artikel

 

FHB is participating in:

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback