DSpace at FH Burgenland logo
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. HAW Burgenland
  3. Departments
  4. Energie & Umwelt
  5. In situ vibration measurements on power modules under operating conditions
 
  • Details

In situ vibration measurements on power modules under operating conditions

Publisher
Elsevier
Source
2012 13th International Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems, EuroSimE
Date Issued
2012-04-16
Author(s)
Czerny, Bernhard  
Nagl, Bernhard 
Lederer, Martin 
Trnka, A. 
Khatibi, Golta 
Thoben, Markus 
DOI
10.1109/ESimE.2012.6191724
Abstract
The subject of this investigation was determination of thermo-mechanically induced displacement of the components inside a power module under operation conditions. It is well known that lifetime of insulated gate bipolar transistor (IGBT) modules is limited by thermo-mechanical fatigue. Wire bonded interconnects inside the IGBTs count as critical sites where crack initiation and failure is observed. In this study the temperature dependent periodic deformation of wire-bonds under operating conditions was determined by using a laser Doppler vibrometer (LDV) and thermal imaging camera. Furthermore finite element analyses (FEA) were conducted to obtain the strain values needed for lifetime assessments.
URI
https://ieeexplore.ieee.org/document/6191724
http://hdl.handle.net/20.500.11790/1661
Type
Konferenzbeitrag

 

FHB is participating in:

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science