Stutterecker, Werner
Official Name
Stutterecker, Werner
Main Affiliation
Akademische Titel
DI(FH) DI, PhD
Email
werner.stutterecker@fh-burgenland.at
Scopus Author ID
55303713600
Status
staff
26 results
Now showing 1 - 10 of 26
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Communication Analysis of Hardware-in-the-Loop Test Method for Heat Pumps and Chillers(Trans Tech Publications, 2019-01); ; 1 545 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, PELTIER HEAT PUMP- Test methods and results of thermoelectric modules(9th International Conference on Indoor Climate of Buildings, Štrbské pleso 2016, 2016); ; ; ; Aschauer, Johann1 40 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 2 223 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Indoor environment challenges in a new type office building – case study(Leykam, 2016-11) ;Nemethova, Ema ;Petráš, Dušan; 90 379 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 1 115 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, HiL-Tests auf Basis von PCP zur Optimierung der energetischen Versorgung von Gebäuden(FH Kufstein Tirol, 2014); ; 2 540 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Simulation of a Magnetocaloric Heat Pump in Building Technology(Leykam, 2017-11); ; ; Increased quality of building envelopes in the last decades leads to decreased heating demands of new buildings and therefore heating devices with lower heating powers are needed. !ere is a lack of suitable solutions in the heating market in the small power range, which can cover small heating loads decentral without distribution losses. In the presented study, the potential of magnetocaloric heating is investigated. Apart from the advantage that no climate-relevant gases are used compared to commonly used compression heat pumps, this technology is suitable for covering low heating requirements. A cornerstone of the investigation is the development of a programme for simulating the behaviour of a building-integrated magnetocaloric heat pump. Target is to determine the effect of the change in basic properties such as the nature of the magnetocaloric material, the magnetic flux density, the working frequency, etc., but also to determine the influence of building parameters on the overall efficiency of the heating system.154 349 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Energy plus standard in buildings constructed by housing associations?(Elsevier, 2012-12); In order to achieve national, European and international energy goals, energy efficiency strategies in the building sector have to be implemented. The passive house standard and low energy standards are already successfully established in single dwelling houses. These high performance standards are starting to penetrate into the sector of housing associations. A case study about an apartment building constructed by a housing association is presented here. It describes the monitoring concept and the results of the 1st year of monitoring. Depending on the definition of the zero energy building standard (extent of loads included in the balancing), the building could be classified as an energy plus building or as a building, which uses more energy, than is supplied by on-site generation. If the building's total energy use (including user specific loads) is defined as load, only 34.5% of these loads were provided by the net energy output of the PV system. If only the heating energy demand is defined as load, the PV system even yielded a surplus of 45.6% of the energy load.1Scopus© Citations 16 205 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 1 97 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 1 139
- «
- 1 (current)
- 2
- 3
- »
